The temperature seems wrong
The temperature reading does not correspond to reality.

- Check the position of the probe: it must be in the cargo compartment, away from sources of direct heat or cold.
- Avoid placing the probe near the refrigeration unit vents, walls or on the floor.
- Make sure the probe is not covered by merchandise or packaging that could affect the reading.
- Compare the probe reading with a reference thermometer to verify accuracy.
- If the difference is more than 2°C, the probe may need to be replaced.
Notes
Small differences between the probe and a reference thermometer (up to 1°C) are normal and within the sensor's tolerance.
Troubleshooting
If the probe shows clearly incorrect values (e.g. -99.9°C), it may be faulty or out of range Bluetooth. Contact support.