What does alarm time mean in minutes

Explanation of the 'alarm time' parameter in the threshold configuration.

cloudchangethresholdsalarms.png
  1. The 'Alarm time in minutes' indicates how many consecutive minutes the temperature must remain outside the threshold before an alarm is generated.
  2. Example: if you set 5 minutes, the temperature must remain below the minimum threshold or above the maximum threshold for at least 5 consecutive minutes.
  3. This mechanism avoids false alarms caused by brief openings of the cargo compartment doors.
  4. A low value (e.g. 1 minute) makes the system very sensitive. A high value (e.g. 15 minutes) reduces alarms.

Notes

For food transport HACCP, an alarm time between 5 and 10 minutes is recommended, depending on the type of goods transported.

Troubleshooting

If you receive too many alarms, increase the alarm time value. If you don't get alarms when you should, reduce it.